69 BIM-collecties gevonden van 8 fabrikant(en) in Verenigde Staten van Amerika
Mitsubishi Electric PAC-MMK40-60BC

PAC-MMK40-60BC

Branch box

Mitsubishi Electric

PAC-MMK40-60BC

Branch box

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
Hisense F15E(E)

F15E(E)

BC Controller

Hisense

F15E(E)

BC Controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Hisense

Downloaden
Mitsubishi Electric CMB-WM350-500F-AA

CMB-WM350-500F-AA

Vertical HBC controller

Mitsubishi Electric

CMB-WM350-500F-AA

Vertical HBC controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
Mitsubishi Heavy Industries Air Conditioning Europe HSB /-W

HSB /-W

Hydrolution - Indoor unit (R410A/R32)

Mitsubishi Heavy Industries Air Conditioning Europe

HSB /-W

Hydrolution - Indoor unit (R410A/R32)

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Heavy Industries Air Conditioning Europe

Downloaden
Remeha Aansluitsets 320/620 ACE Open Verdeler

Aansluitsets 320/620 ACE Open Verdeler

Aansluitset met open verdeler

Remeha

Aansluitsets 320/620 ACE Open Verdeler

Aansluitset met open verdeler

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Remeha

Downloaden
Remeha Aansluitsets 320/620 ACE Warmtewisselaar

Aansluitsets 320/620 ACE Warmtewisselaar

Aansluitset met warmtewisselaar

Remeha

Aansluitsets 320/620 ACE Warmtewisselaar

Aansluitset met warmtewisselaar

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Remeha

Downloaden
Hisense HCHM-N16XA

HCHM-N16XA

BC Controller

Hisense

HCHM-N16XA

BC Controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Hisense

Downloaden
Hisense HCHM-N12XA

HCHM-N12XA

BC Controller

Hisense

HCHM-N12XA

BC Controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Hisense

Downloaden
Hisense HCHM-N08XA

HCHM-N08XA

BC Controller

Hisense

HCHM-N08XA

BC Controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Hisense

Downloaden
Hisense HCHM-N04XA

HCHM-N04XA

BC Controller

Hisense

HCHM-N04XA

BC Controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Hisense

Downloaden
Hisense HCHS

HCHS

BC Controller

Hisense

HCHS

BC Controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Hisense

Downloaden
IVAR MULTIMIX

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

IVAR

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

EMCS-gecertificeerd

.RVT .RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR COMBIMIX

COMBIMIX

Mixing and boosting unit IVAR COMBIMIX for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), two shut-off ball valves for the pump, two fill/drain valves, two automatic air vent valves, three thermometers 0÷80 °C (on delivery and return of boiler circuit and on delivery of mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut-off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M with swivelling nipples (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T5011 included (max differential pressure at mixing valve ends 250 mbar) or set up for outside compensated temperature mixing by integrating axial servomotor IVAR RV 01 or thermoelectric actuator IVAR TE 3061. Differential bypass valve (optional) 0.2÷0.6 bar with half-hard nickel-plated pipe. Pump space 130 mm or 180 mm, G 1”1/2F flat seal connections. Equipped with variable-speed electronic pump WILO4F or variable-speed electronic pump WILO4F-180 or without pump. Accessories: high-temperature kit with pair of manifolds 1” x EUROK with shut-off and lockshield valves CEP/02 I – CEP/03 I (2 ways) – (3 ways), high-temperature kit with pair of simple manifolds 1” x EUROK CEP/02 – CEP/03 (2 ways) – (3 ways), insulation shell ACM 01, threaded spacer for pumps AC 633.

IVAR

COMBIMIX

Mixing and boosting unit IVAR COMBIMIX for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), two shut-off ball valves for the pump, two fill/drain valves, two automatic air vent valves, three thermometers 0÷80 °C (on delivery and return of boiler circuit and on delivery of mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut-off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M with swivelling nipples (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T5011 included (max differential pressure at mixing valve ends 250 mbar) or set up for outside compensated temperature mixing by integrating axial servomotor IVAR RV 01 or thermoelectric actuator IVAR TE 3061. Differential bypass valve (optional) 0.2÷0.6 bar with half-hard nickel-plated pipe. Pump space 130 mm or 180 mm, G 1”1/2F flat seal connections. Equipped with variable-speed electronic pump WILO4F or variable-speed electronic pump WILO4F-180 or without pump. Accessories: high-temperature kit with pair of manifolds 1” x EUROK with shut-off and lockshield valves CEP/02 I – CEP/03 I (2 ways) – (3 ways), high-temperature kit with pair of simple manifolds 1” x EUROK CEP/02 – CEP/03 (2 ways) – (3 ways), insulation shell ACM 01, threaded spacer for pumps AC 633.

EMCS-gecertificeerd

.RVT .RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR VARIMIX

VARIMIX

Distribution and mixing system IVAR VARIMIX for thermal power stations, modular with: hydraulic separator, modular distribution manifold, high-temperature direct flow kit, low-temperature mixing kit, motor for mixing valves, expansion tank, motor for zone ball zone valves. VARIMIX allows to arrange the mechanical room according to a new concept of space and functionality. This solution gives the opportunity to manage multiple thermal areas with different characteristics as truly independent zones in a neat, rational space, thanks to its modular structure and outstanding installation flexibility. In low temperature kits, the mixer valve is available with different hydraulic features and in 3-way or 4-way versions. By producing a mixture even on the return line, it is particularly suitable for older boilers where the return temperature must not be too low to avoid corrosion. Finally, the “LT” modules are specifically designed for applications with low temperature heat sources (for example, heat pumps). Main features: easy to install; compact and neat; fully reversible; versatile and flexible; suitable for heating and cooling applications. Max primary flow rate: 4500 l/h. Max flow rate for each kit: 3000 l/h.

IVAR

VARIMIX

Distribution and mixing system IVAR VARIMIX for thermal power stations, modular with: hydraulic separator, modular distribution manifold, high-temperature direct flow kit, low-temperature mixing kit, motor for mixing valves, expansion tank, motor for zone ball zone valves. VARIMIX allows to arrange the mechanical room according to a new concept of space and functionality. This solution gives the opportunity to manage multiple thermal areas with different characteristics as truly independent zones in a neat, rational space, thanks to its modular structure and outstanding installation flexibility. In low temperature kits, the mixer valve is available with different hydraulic features and in 3-way or 4-way versions. By producing a mixture even on the return line, it is particularly suitable for older boilers where the return temperature must not be too low to avoid corrosion. Finally, the “LT” modules are specifically designed for applications with low temperature heat sources (for example, heat pumps). Main features: easy to install; compact and neat; fully reversible; versatile and flexible; suitable for heating and cooling applications. Max primary flow rate: 4500 l/h. Max flow rate for each kit: 3000 l/h.

EMCS-gecertificeerd

.RVT .RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR TECHNOMIX

TECHNOMIX

IVAR TECHNO TNB cod. 508100: mixing and boosting unit for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), fill/drain valve, manual air vent valve, two thermometers 0÷80 °C (on delivery of boiler circuit and mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T3011 included. Max differential pressure at mixing valve ends 250 mbar. Pump space 130 mm with G 1”1/2F flat seal connections.

IVAR

TECHNOMIX

IVAR TECHNO TNB cod. 508100: mixing and boosting unit for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), fill/drain valve, manual air vent valve, two thermometers 0÷80 °C (on delivery of boiler circuit and mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T3011 included. Max differential pressure at mixing valve ends 250 mbar. Pump space 130 mm with G 1”1/2F flat seal connections.

EMCS-gecertificeerd

.RVT .RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
Mitsubishi Electric City Multi BC Controllers CMB-M-V-J1

City Multi BC Controllers CMB-M-V-J1

BC controller

Mitsubishi Electric

City Multi BC Controllers CMB-M-V-J1

BC controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
Mitsubishi Electric City Multi BC Controllers CMB-M-V-JA1

City Multi BC Controllers CMB-M-V-JA1

BC controller

Mitsubishi Electric

City Multi BC Controllers CMB-M-V-JA1

BC controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
Mitsubishi Electric City Multi BC Controllers CMB-P-V-KA1

City Multi BC Controllers CMB-P-V-KA1

BC controller

Mitsubishi Electric

City Multi BC Controllers CMB-P-V-KA1

BC controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
Mitsubishi Electric City Multi BC Controllers CMB-M-V-KB1

City Multi BC Controllers CMB-M-V-KB1

BC controller

Mitsubishi Electric

City Multi BC Controllers CMB-M-V-KB1

BC controller

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
ELCO VARION C-POWER

VARION C-POWER

Combined Heat and Power Units

ELCO

VARION C-POWER

Combined Heat and Power Units

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

ELCO

Downloaden
Mitsubishi Electric Ecodan PAC-MK-BC(B)

Ecodan PAC-MK-BC(B)

BC controllers Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PAC-MK-BC(B)

BC controllers

Place directly in Revit and AutoCAD using the free Mitsubishi Electric System Designer App

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
Mitsubishi Electric City Multi BC Controllers CMB-PV-J/K(A) (Model 2018)

City Multi BC Controllers CMB-PV-J/K(A) (Model 2018)

BC controller Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

City Multi BC Controllers CMB-PV-J/K(A) (Model 2018)

BC controller

Place directly in Revit and AutoCAD using the free Mitsubishi Electric System Designer App

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
Mitsubishi Electric City Multi BC Controllers CMB-PV-G/H

City Multi BC Controllers CMB-PV-G/H

BC Controller Plaats direct in Revit en AutoCAD met de gratis [a href="https://store.mepcontent.com/nl/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

City Multi BC Controllers CMB-PV-G/H

BC Controller

Plaats direct in Revit en AutoCAD met de gratis Mitsubishi Electric System Designer App

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
IVAR IVARSAT-L-LE

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR IVARSAT-HL-HLE

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR IVARSAT-H

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR IVARSAT-H VNR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

IVAR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR BRASS-ROD MANIFOLDS_CI600N

BRASS-ROD MANIFOLDS_CI600N

Flow manifold with flow meter/adjuster FLUXER (0-5 l/min) and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_CI600N

Flow manifold with flow meter/adjuster FLUXER (0-5 l/min) and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR BRASS-ROD MANIFOLDS_CS502N

BRASS-ROD MANIFOLDS_CS502N

Plain manifold with EUROK connections. Manifolds can be used as supply or return manifolds. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_CS502N

Plain manifold with EUROK connections. Manifolds can be used as supply or return manifolds. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR BRASS-ROD MANIFOLDS_CI562MN

BRASS-ROD MANIFOLDS_CI562MN

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_CI562MN

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR BRASS-ROD MANIFOLDS CI552N

BRASS-ROD MANIFOLDS CI552N

Flow manifold with micrometric dually adjusted lockshields and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C.Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI552N

Flow manifold with micrometric dually adjusted lockshields and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C.Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR BRASS-ROD MANIFOLDS CI554MN

BRASS-ROD MANIFOLDS CI554MN

Return manifold with manually operated isolation valves and EUROK connections. Manifolds can be used as return manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI554MN

Return manifold with manually operated isolation valves and EUROK connections. Manifolds can be used as return manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR BRASS-ROD MANIFOLDS_CI595MN

BRASS-ROD MANIFOLDS_CI595MN

Kit made of flow manifold with flow meter/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_CI595MN

Kit made of flow manifold with flow meter/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR BRASS-ROD MANIFOLDS_KC01KC

BRASS-ROD MANIFOLDS_KC01KC

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_KC01KC

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR BRASS-ROD MANIFOLDS KC02KC

BRASS-ROD MANIFOLDS KC02KC

Kit made of flow manifold with flow meters/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS KC02KC

Kit made of flow manifold with flow meters/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR IVARSAT-H

IVARSAT-H

The satellite module IvarSAT-H independently manages high-temperature heating (direct circuit) in centralized systems and instantaneous production of domestic hot water in each apartment. Optional equipment: “R” with recirculation circuit complete with pump, “1” with high-temperature domestic water outlet. Mode of installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover painted white 860-960×700×110-160 mm, “M” in wall hanging box made of aluminium painted white 722×600×150 mm. Optional accessories: heat meter, flow meter, electrothermal head, thermostatic head, axial motor.

IVAR

IVARSAT-H

The satellite module IvarSAT-H independently manages high-temperature heating (direct circuit) in centralized systems and instantaneous production of domestic hot water in each apartment.
Optional equipment: “R” with recirculation circuit complete with pump, “1” with high-temperature domestic water outlet.
Mode of installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover painted white 860-960×700×110-160 mm, “M” in wall hanging box made of aluminium painted white 722×600×150 mm.
Optional accessories: heat meter, flow meter, electrothermal head, thermostatic head, axial motor.

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

IVAR

Downloaden
Remeha Connection Sets 310/610 Eco Pro

Connection Sets 310/610 Eco Pro

Connector sets from Remeha

Remeha

Connection Sets 310/610 Eco Pro

Connector sets from Remeha

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Remeha

Downloaden
IVAR IVARPRESS – PRESS FITTINGS – Line

IVARPRESS – PRESS FITTINGS – Line

IVARPRESS is an IVAR press fitting studied and tested to be used with B crimper profile. The geometry of the fitting, designed for ideal coupling between pipe and fitting ensuing pressing, and the windows on the bushing holder, to verify correct insertion of the pipe and two O-rings in peroxide EPDM on each terminal, are all details which help to guarantee the usability and reliability of the product. The body is made of CW617N nickel-finished brass on the outer surface and yellow for all other parts in contact with fluid in conformity with the latest standards-regulations for drinking water plant. Available in a wide range of configurations and sizes.

IVAR

IVARPRESS – PRESS FITTINGS – Line

IVARPRESS is an IVAR press fitting studied and tested to be used with B crimper profile. The geometry of the fitting, designed for ideal coupling between pipe and fitting ensuing pressing, and the windows on the bushing holder, to verify correct insertion of the pipe and two O-rings in peroxide EPDM on each terminal, are all details which help to guarantee the usability and reliability of the product.
The body is made of CW617N nickel-finished brass on the outer surface and yellow for all other parts in contact with fluid in conformity with the latest standards-regulations for drinking water plant.
Available in a wide range of configurations and sizes.

EMCS-gecertificeerd

.RVT .PDF

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR MPLC MULTI PRESS WITH LEAKAGE FUNCTION CUPHIN - Line

MPLC MULTI PRESS WITH LEAKAGE FUNCTION CUPHIN - Line

MULTI•PRESS•LEAK•CUPHIN is the new press fitting designed to guarantee water leakage in case of failed pressing and to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U). The absence of sealing if not pressed is a function which is especially on demand on the market to avoid problems and damage in case of forgotten pressing: thanks to the system test, the installer can immediately identify leaks and repair them by correctly pressing the fitting. Available in a wide range of configurations and sizes. Fitting body made of Cuphin CW724R.

IVAR

MPLC MULTI PRESS WITH LEAKAGE FUNCTION CUPHIN - Line

MULTI•PRESS•LEAK•CUPHIN is the new press fitting designed to guarantee water leakage in case of failed pressing and to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U). The absence of sealing if not pressed is a function which is especially on demand on the market to avoid problems and damage in case of forgotten pressing: thanks to the system test, the installer can immediately identify leaks and repair them by correctly pressing the fitting.
Available in a wide range of configurations and sizes.

Fitting body made of Cuphin CW724R.

EMCS-gecertificeerd

.RVT .PDF

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR MPL PRESS FITTINGS WITH LEAKAGE FUNCTION – Line

MPL PRESS FITTINGS WITH LEAKAGE FUNCTION – Line

MULTI•PRESS•LEAK is the new press fitting designed to guarantee water leakage in case of failed pressing and to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U). The absence of sealing if not pressed is a function which is especially on demand on the market to avoid problems and damage in case of forgotten pressing: thanks to the system test, the installer can immediately identify leaks and repair them by correctly pressing the fitting. Available in a wide range of configurations and sizes.

IVAR

MPL PRESS FITTINGS WITH LEAKAGE FUNCTION – Line

MULTI•PRESS•LEAK is the new press fitting designed to guarantee water leakage in case of failed pressing and to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U). The absence of sealing if not pressed is a function which is especially on demand on the market to avoid problems and damage in case of forgotten pressing: thanks to the system test, the installer can immediately identify leaks and repair them by correctly pressing the fitting.
Available in a wide range of configurations and sizes.

EMCS-gecertificeerd

.RVT .PDF

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR MP PRESS FITTINGS - Line

MP PRESS FITTINGS - Line

MULTI•PRESS is an IVAR press fitting studied and tested to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U). The geometry of the fitting, designed for ideal coupling between pipe and fitting ensuing pressing, and the windows on the bushing holder, to verify correct insertion of the pipe and two O-rings in peroxide EPDM on each terminal, are all details which help to guarantee the usability and reliability of the product. Available in a wide range of configurations and sizes.

IVAR

MP PRESS FITTINGS - Line

MULTI•PRESS is an IVAR press fitting studied and tested to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U).
The geometry of the fitting, designed for ideal coupling between pipe and fitting ensuing pressing, and the windows on the bushing holder, to verify correct insertion of the pipe and two O-rings in peroxide EPDM on each terminal, are all details which help to guarantee the usability and reliability of the product.
Available in a wide range of configurations and sizes.

EMCS-gecertificeerd

.RVT .PDF

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR IS-BOX

IS-BOX

IS-BOX is a box with a pair of pre-installed 3+1 and 4+1 outlet sanitary manifolds, suitable for wall recessing even in bathrooms covered with tiles or valuable materials. The reduced size allows it to be installed in brick or plasterboard walls with a minimum thickness of 60 mm. The manifolds are compatible with drinking water and the inlets can be shut off by screw sealing valves and replaceable headworks. Available in two colours (white and chrome), also in the completely inspectable version.

IVAR

IS-BOX

IS-BOX is a box with a pair of pre-installed 3+1 and 4+1 outlet sanitary manifolds, suitable for wall recessing even in bathrooms covered with tiles or valuable materials. The reduced size allows it to be installed in brick or plasterboard walls with a minimum thickness of 60 mm. The manifolds are compatible with drinking water and the inlets can be shut off by screw sealing valves and replaceable headworks. Available in two colours (white and chrome), also in the completely
inspectable version.

EMCS-gecertificeerd

.RFA .PDF

Verdeler Verwarming en Koeling

IVAR

Downloaden
IVAR IVAR ESAT DUAL

IVAR ESAT DUAL

IVAR E-SAT DUAL is a double heat exchanger satellite module which allows on-site production of DHW and hot water for the heating system, with only AFS connections and technical water supply/return. Thanks to the integrated electronics IVAR E-SAT modulates the technical water flow to guarantee a low return temperature to the boiler. The double exchanger solution, completely separating the centralized system from the domestic one, guarantees easy maintenance of the single user system. IVAR ESAT DUAL can be equipped with differential pressure valves and shut-off valves kit.

IVAR

IVAR ESAT DUAL

IVAR E-SAT DUAL is a double heat exchanger satellite module which allows on-site production of DHW and hot water for the heating system, with only AFS connections and technical water supply/return. Thanks to the integrated electronics IVAR E-SAT modulates the technical water flow to guarantee a low return temperature to the boiler. The double exchanger solution, completely separating the centralized system from the domestic one, guarantees easy maintenance of the single user system. IVAR ESAT DUAL can be equipped with differential pressure valves and shut-off valves kit.

EMCS-gecertificeerd

.RFA .PDF

Verdeler Verwarming en Koeling

IVAR

Downloaden
Mitsubishi Electric FAQ IMP Copper pipes Mitsubishi

FAQ IMP Copper pipes Mitsubishi

This manual describes how you can create a new pipe and add Imperial Diameters in Revit MEP. Plaats direct in Revit en AutoCAD met de gratis [a href="https://store.mepcontent.com/nl/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

FAQ IMP Copper pipes Mitsubishi

This manual describes how you can create a new pipe and add Imperial Diameters in Revit MEP.

Plaats direct in Revit en AutoCAD met de gratis Mitsubishi Electric System Designer App

EMCS-gecertificeerd

.PDF

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
Therminon Composite unit model District Heating Nuon

Composite unit model District Heating Nuon

1-16-GROUP COMP UNIT MODEL: NUON DISTRICT HEATING

Therminon

Composite unit model District Heating Nuon

1-16-GROUP COMP UNIT MODEL: NUON DISTRICT HEATING

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model District Heating Essent

Composite unit model District Heating Essent

1-16-GROUP COMP UNIT MODEL: ESSENT DISTRICT HEATING

Therminon

Composite unit model District Heating Essent

1-16-GROUP COMP UNIT MODEL: ESSENT DISTRICT HEATING

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model OEM LTV gescheiden systeem verwarming/koeling

Composite unit model OEM LTV gescheiden systeem verwarming/koeling

1-16-GROUP OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS + SPLIT SYSTEM HEAT EXCHANGER PACK 4-PIPE / 5.5 KVS THERM. VALVES / COOLING VALVE NC

Therminon

Composite unit model OEM LTV gescheiden systeem verwarming/koeling

1-16-GROUP OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS + SPLIT SYSTEM HEAT EXCHANGER PACK 4-PIPE / 5.5 KVS THERM. VALVES / COOLING VALVE NC

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model OEM LTV 4 pijps aansluiting

Composite unit model OEM LTV 4 pijps aansluiting

1-16-GR OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS + SET 4-PIPE CONN. 3/4'' + 4 X 5.5 KVS THERM. VALVES

Therminon

Composite unit model OEM LTV 4 pijps aansluiting

1-16-GR OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS + SET 4-PIPE CONN. 3/4'' + 4 X 5.5 KVS THERM. VALVES

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model OEM LTV gescheiden systeem met dubbele warmtewisselaar

Composite unit model OEM LTV gescheiden systeem met dubbele warmtewisselaar

1-16-GROUP OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS + SPLIT SYSTEM / DOUBLE HEAT EXCHANGER PACK + 5.5 KVS THERM. VALVES

Therminon

Composite unit model OEM LTV gescheiden systeem met dubbele warmtewisselaar

1-16-GROUP OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS + SPLIT SYSTEM / DOUBLE HEAT EXCHANGER PACK + 5.5 KVS THERM. VALVES

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model OEM LTV 3 pijps aansluiting

Composite unit model OEM LTV 3 pijps aansluiting

1-16-GROUP OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS + SET 3-PIPE CONN. 3/4'' + 3 X 5.5 KVS THERM. VALVES

Therminon

Composite unit model OEM LTV 3 pijps aansluiting

1-16-GROUP OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS + SET 3-PIPE CONN. 3/4'' + 3 X 5.5 KVS THERM. VALVES

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model Industrie 3 bars

Composite unit model Industrie 3 bars

1-20-GROUP COMP UNIT MODEL: INDUSTRY / 3-BARS

Therminon

Composite unit model Industrie 3 bars

1-20-GROUP COMP UNIT MODEL: INDUSTRY / 3-BARS

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model OEM LTV gescheiden systeem

Composite unit model OEM LTV gescheiden systeem

1-16GROUP OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS + SPLIT SYSTEM / HEAT EXCHANGER PACK

Therminon

Composite unit model OEM LTV gescheiden systeem

1-16GROUP OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS + SPLIT SYSTEM / HEAT EXCHANGER PACK

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model OEM Industrie

Composite unit model OEM Industrie

1-20-GROUP OEM INDUSTRY / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS

Therminon

Composite unit model OEM Industrie

1-20-GROUP OEM INDUSTRY / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model Industrie 4 balks

Composite unit model Industrie 4 balks

1-20-GROUP COMP UNIT MODEL: INDUSTRY / 4-BARS

Therminon

Composite unit model Industrie 4 balks

1-20-GROUP COMP UNIT MODEL: INDUSTRY / 4-BARS

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model Industrie

Composite unit model Industrie

1-20-GROUP COMP UNIT MODEL: INDUSTRY

Therminon

Composite unit model Industrie

1-20-GROUP COMP UNIT MODEL: INDUSTRY

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Unit model District Heating Nuon DA PN6

Unit model District Heating Nuon DA PN6

1-12-GROUP NUON DISTRICT HEATING DOUBLE ADJUSTABLE / PN6

Therminon

Unit model District Heating Nuon DA PN6

1-12-GROUP NUON DISTRICT HEATING DOUBLE ADJUSTABLE / PN6

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Unit model District Heating Essent DA PN6

Unit model District Heating Essent DA PN6

1-12-GROUP ESSENT DISTRICT HEATING DOUBLE ADJUSTABLE / PN6

Therminon

Unit model District Heating Essent DA PN6

1-12-GROUP ESSENT DISTRICT HEATING DOUBLE ADJUSTABLE / PN6

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Unit model LTV compact DA gescheiden systeem

Unit model LTV compact DA gescheiden systeem

1-16-GROUP LTV COMPACT DOUBLE ADJUSTABLE + SPLIT SYSTEM / HEAT EXCHANGER PACK

Therminon

Unit model LTV compact DA gescheiden systeem

1-16-GROUP LTV COMPACT DOUBLE ADJUSTABLE + SPLIT SYSTEM / HEAT EXCHANGER PACK

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Unit model LTV compact DA

Unit model LTV compact DA

1-16 GROUP LTV COMPACT DOUBLE ADJUSTABLE

Therminon

Unit model LTV compact DA

1-16 GROUP LTV COMPACT DOUBLE ADJUSTABLE

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Unit model 5000 DA

Unit model 5000 DA

1-16-GROUP 5000 DOUBLE ADJUSTABLE

Therminon

Unit model 5000 DA

1-16-GROUP 5000 DOUBLE ADJUSTABLE

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model LTV gescheiden systeem met dubbele warmtewisselaar

Composite unit model LTV gescheiden systeem met dubbele warmtewisselaar

1-16-GROUP COMP UNIT MODEL: LTV + SPLIT SYSTEM / DOUBLE HEAT EXCHANGER PACK + 5.5 KVS THERM. VALVES

Therminon

Composite unit model LTV gescheiden systeem met dubbele warmtewisselaar

1-16-GROUP COMP UNIT MODEL: LTV + SPLIT SYSTEM / DOUBLE HEAT EXCHANGER PACK + 5.5 KVS THERM. VALVES

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model LTV gescheiden systeem verwarming/koeling

Composite unit model LTV gescheiden systeem verwarming/koeling

1-16-GROUP COMP UNIT MODEL: LTV + SPLIT SYSTEM HEAT EXCHANGER PACK 4-PIPE / 5.5 KVS THERM. VALVES / COOLING VALVE NC

Therminon

Composite unit model LTV gescheiden systeem verwarming/koeling

1-16-GROUP COMP UNIT MODEL: LTV + SPLIT SYSTEM HEAT EXCHANGER PACK 4-PIPE / 5.5 KVS THERM. VALVES / COOLING VALVE NC

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model LTV 3 pijps aansluiting

Composite unit model LTV 3 pijps aansluiting

1-16-GROUP COMP UNIT MODEL: LTV + SET 3-PIPE CONN. 3/4''+ 3 X 5.5 KVS THERM. VALVES

Therminon

Composite unit model LTV 3 pijps aansluiting

1-16-GROUP COMP UNIT MODEL: LTV + SET 3-PIPE CONN. 3/4''+ 3 X 5.5 KVS THERM. VALVES

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model LTV gescheiden systeem

Composite unit model LTV gescheiden systeem

16-GROUP COMP UNIT MODEL: LTV + SPLIT SYSTEM / HEAT EXCHANGER PACK

Therminon

Composite unit model LTV gescheiden systeem

16-GROUP COMP UNIT MODEL: LTV + SPLIT SYSTEM / HEAT EXCHANGER PACK

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model LTV 4 pijps aansluiting

Composite unit model LTV 4 pijps aansluiting

1-16-GROUP COMP UNIT MODEL: LTV + SET 4-PIPE CONN. 3/4'' + 4 X 5.5 KVS THERM. VALVES

Therminon

Composite unit model LTV 4 pijps aansluiting

1-16-GROUP COMP UNIT MODEL: LTV + SET 4-PIPE CONN. 3/4'' + 4 X 5.5 KVS THERM. VALVES

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model OEM LTV

Composite unit model OEM LTV

1-16-GROUP OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS

Therminon

Composite unit model OEM LTV

1-16-GROUP OEM LTV / FLOWMETERS + COMP. EUROCONE EASY-CONNECTORS

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Therminon Composite unit model LTV

Composite unit model LTV

1-16-GROUP COMPOSITE UNIT MODEL: LTV

Therminon

Composite unit model LTV

1-16-GROUP COMPOSITE UNIT MODEL: LTV

EMCS-gecertificeerd

.RFA

Verdeler Verwarming en Koeling

Therminon

Downloaden
Mitsubishi Electric City Multi HBC Controllers (HVRF)

City Multi HBC Controllers (HVRF)

BC Controller Plaats direct in Revit en AutoCAD met de gratis [a href="https://store.mepcontent.com/nl/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

City Multi HBC Controllers (HVRF)

BC Controller

Plaats direct in Revit en AutoCAD met de gratis Mitsubishi Electric System Designer App

EMCS-gecertificeerd

.DWG .RFA .IFC

Verdeler Verwarming en Koeling

Mitsubishi Electric

Downloaden
Giacomini R551

R551

Verdeler uit geprofileerde messingstang

Giacomini

R551

Verdeler uit geprofileerde messingstang

EMCS-gecertificeerd

.DWG .RFA

Verdeler Verwarming en Koeling

Giacomini

Downloaden